Skip to main content

Quality Analyst 6.1 Upgrade Patch

How to patch NWA Quality Analyst 6.1 to release 2.3.283
 

Only releases 2.3.157, 2.3.175, 2.3.185, 2.3.237, 2.3.245, and 2.3.278 can be patched, release 2.3.144 must be replaced entirely.

Important Notes About Patching NWA Quality Analyst

Single User Installation

Before patching, check which patch you need: Run Quality Analyst, open the Help menu, select About Quality Analyst, and confirm that the release number is 2.3.157, 2.3.175, 2.3.185, 2.3.237, 2.3.245, or 2.3.278.

You will need the original NWA Quality Analyst 6.1 CD to install the patch.

These patches modify the portions of NWA Quality Analyst 6.1 that have changed. Do not discard your original serial-numbered CD.

Download the patch file.

After downloading, double-click the downloaded file to install the patch. When prompted, insert the NWA Quality Analyst 6.1 CD.

After patching, you should test the patch by running Quality Analyst, opening the Help menu, selecting About Quality Analyst, and confirming that the release number is 2.3.283.


LAN Network Installation Point

The recommended method of patching a LAN installation is to patch the Network Installation Point, and then reinstall NWA Quality Analyst on each of the workstations. The new version will replace the previous version.

To patch the Network Installation Point, use the command line:

msiexec /p QA6283.msp /a setup.msi

Setup.msi is the msi file in the Network Installation Point, so the command above may need to include the paths to the msp and msi files:

msiexec /p "C:\QA Patch\QA6283.msp" /a G:\NWAQA\setup.msi

It is best to run the patch from the computer that contains the Network Installation Point. After patching, NWA Quality Analyst can be reinstalled on each workstation.

Before patching, check which patch you need: Run Quality Analyst, open the Help menu, select About Quality Analyst, and confirm that the release number is 2.3.157, 2.3.175, 2.3.185, 2.3.237, 2.3.245, or 2.3.278.


LAN Workstation

An alternative to reinstalling NWA Quality Analyst on the workstations is to patch each workstation. To patch a workstation, double-click on QA6283.msp. The Network Installation Point will need to be available, and it must contain the previous version of NWA Quality Analyst, not the new version.

If the Network Installation Point has been patched to the new version, workstations can no longer be patched. NWA Quality Analyst must be reinstalled on each workstation.


Download Quality Analyst 6.1 Patch

Patch releases 2.3.157, 2.3.175, 2.3.185, 2.3.237, 2.3.245, and 2.3.278 to release 2.3.283

QA6283.MSP (After downloading, double-click QA6283.MSP to install.)

A copy of these release notes along with a list of the changes addressed in this release of QA 6.1 can be downloaded by selecting the following link:

QA61PatchWeb283.pdf